Curtis 732 SERIES Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Multímetros Curtis 732 SERIES. 700/732 SERIES - Curtis Instruments Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 11
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Read Instructions Carefully!
5mm HOUR METERS & COUNTERS
700/732 SERIES
®
CURTIS INSTRUMENTS, INC.
200 Kisco Ave.
Mount Kisco, New York 10549
914-666-2971 Tel
914-666-2188 Fax
www.curtisinstruments.com
53004 Rev. G 9/14
Vista de página 0
1 2 3 4 5 6 ... 10 11

Resumo do Conteúdo

Página 1 - 700/732 SERIES

Read Instructions Carefully!5mm HOUR METERS & COUNTERS700/732 SERIES®CURTIS INSTRUMENTS, INC.200 Kisco Ave.Mount Kisco, New York 10549914-666-297

Página 2 - SAFETY INSTRUCTIONS

16 17703 Counter continued The input signal must be applied for 1/2 second minimum (AC/DC model) or for 1 millisecond mimimum (DC Only model). If powe

Página 3 - 1. MODEL ENCODEMENT

18 195. TROUBLESHOOTINGTo maximize the life of this meter, please read all instructions carefully and review Safety Precautions on inside front cover

Página 4 - 732 Model Encodement Only

TABLE OF CONTENTS1. Model Encodement 22. Technical Specifications 2.1 Electrical 6 2.2 Mechanical 10 2.3 Environmental 123. Installati

Página 5 - 2. TECHNICAL SPECIFICATIONS

2 3Example: 7 01 G R 001 0512D0612A N FunctionCaseStyleResetSequentialCodeNominalVoltage1 3 52 4 6LogoFunction1 21. MODEL ENCODEMENT(All mod

Página 6 - Impedance

4 5Example: 732 N 2 3 001 N FunctionCaseStyleLED VoltageSequentialCode1 3 52 4LogoFunction120 2-wire Hour Meter, no enable; LE

Página 7 - 2.2 Mechanical

6 72. TECHNICAL SPECIFICATIONS2.1 Electrical Operating Voltage 700 SeriesThe operating voltage ranges specified apply to voltages connected between te

Página 8 - 3. INSTALLATION

8 9Operating Current(All models except 732)The maximum operating current at terminal 1 is tabulated below for each nominal operating voltage limit.

Página 9 - 4. OPERATION

10 11Case Bezel Shape Terminals Max Pins Mounting Lens Matrl. Case Matrl. Bezel Material Panel Cutout (mm) Panel Cutout (in.)F Hexagonal 1/4” Faston 4

Página 10 - 732 Hour Meter continued

12 133. INSTALLATIONV+: Operating voltage;V–: Common (ground);I: Enable (optional, use operating voltage to power this pin to record elapsed time [701

Página 11 - 7. WARRANTY

14 154. OPERATIONNOTE: All models display an 8 in all digits for 1 sec. at power-up.700 Hour Meter (AC/DC)To Display & Operate: Apply DC+ or AC h

Comentários a estes Manuais

Sem comentários